Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Biomed Eng ; 51(9): 1950-1964, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37436564

RESUMEN

The endothelium in the coronary arteries is subject to wall shear stress and vessel wall strain, which influences the biology of the arterial wall. This study presents vessel-specific fluid-structure interaction (FSI) models of three coronary arteries, using directly measured experimental geometries and boundary conditions. FSI models are used to provide a more physiologically complete representation of vessel biomechanics, and have been extended to include coronary bending to investigate its effect on shear and strain. FSI both without- and with-bending resulted in significant changes in all computed shear stress metrics compared to CFD (p = 0.0001). Inclusion of bending within the FSI model produced highly significant changes in Time Averaged Wall Shear Stress (TAWSS) + 9.8% LAD, + 8.8% LCx, - 2.0% RCA; Oscillatory Shear Index (OSI) + 208% LAD, 0% LCx, + 2600% RCA; and transverse wall Shear Stress (tSS) + 180% LAD, + 150% LCx and + 200% RCA (all p < 0.0001). Vessel wall strain was homogenous in all directions without-bending but became highly anisotropic under bending. Changes in median cyclic strain magnitude were seen for all three vessels in every direction. Changes shown in the magnitude and distribution of shear stress and wall strain suggest that bending should be considered on a vessel-specific basis in analyses of coronary artery biomechanics.


Asunto(s)
Vasos Coronarios , Modelos Cardiovasculares , Fenómenos Biomecánicos , Vasos Coronarios/fisiología , Simulación por Computador , Corazón , Estrés Mecánico , Hemodinámica
2.
iScience ; 26(6): 106760, 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37235059

RESUMEN

Blood flow is a key regulator of atherosclerosis. Disturbed blood flow promotes atherosclerotic plaque development, whereas normal blood flow protects against plaque development. We hypothesized that normal blood flow is also therapeutic, if it were able to be restored within atherosclerotic arteries. Apolipoprotein E-deficient (ApoE-/-) mice were initially instrumented with a blood flow-modifying cuff to induce plaque development and then five weeks later the cuff was removed to allow restoration of normal blood flow. Plaques in decuffed mice exhibited compositional changes that indicated increased stability compared to plaques in mice with the cuff maintained. The therapeutic benefit of decuffing was comparable to atorvastatin and the combination had an additive effect. In addition, decuffing allowed restoration of lumen area, blood velocity, and wall shear stress to near baseline values, indicating restoration of normal blood flow. Our findings demonstrate that the mechanical effects of normal blood flow on atherosclerotic plaques promote stabilization.

3.
PLoS One ; 18(1): e0280385, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36662769

RESUMEN

BACKGROUND: This work aims to present a fast, affordable, and reproducible three-cell co-culture system that could represent the different cellular mechanisms of atherosclerosis, extending from atherogenesis to pathological intimal thickening. METHODS AND RESULTS: We built four culture models: (i) Culture model #1 (representing normal arterial intima), where human coronary artery endothelial cells were added on top of Matrigel-coated collagen type I matrix, (ii) Culture model #2 (representing atherogenesis), which demonstrated the subendothelial accumulation and oxidative modification of low-density lipoproteins (LDL), (iii) Culture model #3 (representing intimal xanthomas), which demonstrated the monocyte adhesion to the endothelial cell monolayer, transmigration into the subendothelial space, and transformation to lipid-laden macrophages, (iv) Culture model #4 (representing pathological intimal thickening), which incorporated multiple layers of human coronary artery smooth muscle cells within the matrix. Coupling this model with different shear stress conditions revealed the effect of low shear stress on the oxidative modification of LDL and the upregulation of pro-inflammatory molecules and matrix-degrading enzymes. Using electron microscopy, immunofluorescence confocal microscopy, protein and mRNA quantification assays, we showed that the behaviors exhibited by the endothelial cells, macrophages and vascular smooth muscle cells in these models were very similar to those exhibited by these cell types in nascent and intermediate atherosclerotic plaques in humans. The preparation time of the cultures was 24 hours. CONCLUSION: We present three-cell co-culture models of human atherosclerosis. These models have the potential to allow cost- and time-effective investigations of the mechanobiology of atherosclerosis and new anti-atherosclerotic drug therapies.


Asunto(s)
Aterosclerosis , Células Endoteliales , Humanos , Técnicas de Cocultivo , Células Endoteliales/metabolismo , Músculo Liso Vascular/metabolismo , Aterosclerosis/metabolismo , Macrófagos/metabolismo , Miocitos del Músculo Liso/metabolismo
4.
J Mech Behav Biomed Mater ; 137: 105545, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36368188

RESUMEN

Complex patterns of hemodynamic wall shear stress occur in regions of arterial branching and curvature. Areas within these regions can be highly susceptible to atherosclerosis. Although many studies have characterized the response of vascular endothelial cells to shear stress in a categorical manner, our study herein addresses the need of characterizing endothelial behaviors over a continuous range of shear stress conditions that reflect the extensive variations seen in the vasculature. We evaluated the response of human umbilical vein endothelial cell monolayers to orbital flow at 120, 250, and 350 revolutions per minute (RPM) for 24 and 72 h. The orbital shaker model uniquely provides a continuous range of shear stress conditions from low and multidirectional at the center of each well of a culture plate to high and unidirectional at the periphery. We found distinct patterns of endothelial nuclear area, nuclear major and minor diameters, nuclear aspect ratio, and expression of endothelial nitric oxide synthase over this range of shear conditions and relationships were fit with linear and, where appropriate, power functions. Nuclear area was particularly sensitive with increases in the low and multidirectional WSS region that incrementally decreased as WSS became higher in magnitude and more unidirectional over the radius of the cell layers. The patterns of all endothelial behaviors exhibited high correlations (positive and negative) with metrics of shear stress magnitude and directionality that have been shown to strongly associate with atherosclerosis. Our findings demonstrate the exquisite sensitivity of these endothelial behaviors to incremental changes in shear stress magnitude and directionality, and provide critical quantitation of these relationships for predicting the susceptibility of an arterial segment to diseases such as atherosclerosis, particularly within complex flow environments in the vasculature such as around bifurcations.


Asunto(s)
Aterosclerosis , Óxido Nítrico Sintasa de Tipo III , Humanos , Óxido Nítrico Sintasa de Tipo III/metabolismo , Endotelio Vascular , Estrés Mecánico , Células Endoteliales de la Vena Umbilical Humana
5.
Front Bioeng Biotechnol ; 11: 1300830, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38312508

RESUMEN

Introduction: Cataract surgery permanently alters the mechanical environment of the lens capsule by placing a hole in the anterior portion and implanting an intraocular lens (IOL) that has a very different geometry from the native lens. We hypothesized that implant configuration and mechanical interactions with the post-surgical lens capsule play a key role in determining long-term fibrotic remodeling. Methods: We developed the first finite element-growth and remodeling (FE-G&R) model of the post-surgical lens capsule to evaluate how implantation of an IOL with and without a capsular tension ring (CTR) impacted evolving lens capsule mechanics and associated fibrosis over time after cataract surgery. Results: Our models predicted that implantation of a CTR with the IOL into the post-surgical lens capsule reduced the mechanical perturbation, thickening, and stiffening along the visual axis in both the remnant anterior and posterior portions compared to implantation of the IOL alone. Discussion: These findings align with patient studies and suggest that implantation of a CTR with the IOL during routine cataract surgery would attenuate the incidence of visually-debilitating capsule fibrosis. Our work demonstrates that use of such modeling techniques has substantial potential to aid in the design of better surgical strategies and implants.

6.
J Biomech ; 136: 111054, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35344827

RESUMEN

Accommodation alters the shape of the eye lens to change focus from distant to near vision. This function declines with age in the development of presbyopia and most people experience a near total loss of accommodative ability by 55 years. Currently, there are no surgical procedures that correct presbyopia, but considerable work has been done in the development of accommodative intraocular lenses (AIOLs) implanted during cataract surgery. Despite these efforts, AIOLs only restore âˆ¼ 20% of youthful accommodative amplitude and they suffer from high rates of visually-debilitating fibrosis. An important design tool that is lacking that could aid in improving AIOL designs is modeling. Herein, we addressed this need through the development of a fully 3-D finite element model that was used to predict the behavior of a dual-optic AIOL implanted within the post-surgical lens capsule. Models of the native human lens were developed to identify the stress-free configuration of the lens capsule needed to accurately predict the accommodated state of the lens and the configuration of the zonular traction needed for the disaccommodated state. The AIOL model demonstrated the functional importance of implant stiffness and predicted an approximately linear relationship between zonular traction magnitude and axial displacement of the optics. To our knowledge, this is the first model that can be used to gain insights into AIOL efficacy. It provides a foundation for continued development of a predictive tool that could ultimately improve AIOL designs that seek to restore youthful accommodative function.


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Presbiopía , Acomodación Ocular , Humanos , Persona de Mediana Edad , Presbiopía/cirugía , Diseño de Prótesis
7.
PLoS One ; 16(12): e0260606, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34882722

RESUMEN

Atherosclerosis is a lipid-driven chronic inflammatory disease that leads to the formation of plaques in the inner lining of arteries. Plaques form over a range of phenotypes, the most severe of which is vulnerable to rupture and causes most of the clinically significant events. In this study, we evaluated the efficacy of nanoparticles (NPs) to differentiate between two plaque phenotypes based on accumulation kinetics in a mouse model of atherosclerosis. This model uses a perivascular cuff to induce two regions of disturbed wall shear stress (WSS) on the inner lining of the instrumented artery, low (upstream) and multidirectional (downstream), which, in turn, cause the development of an unstable and stable plaque phenotype, respectively. To evaluate the influence of each WSS condition, in addition to the final plaque phenotype, in determining NP uptake, mice were injected with NPs at intermediate and fully developed stages of plaque growth. The kinetics of artery wall uptake were assessed in vivo using dynamic contrast-enhanced magnetic resonance imaging. At the intermediate stage, there was no difference in NP uptake between the two WSS conditions, although both were different from the control arteries. At the fully-developed stage, however, NP uptake was reduced in plaques induced by low WSS, but not multidirectional WSS. Histological evaluation of plaques induced by low WSS revealed a significant inverse correlation between the presence of smooth muscle cells and NP accumulation, particularly at the plaque-lumen interface, which did not exist with other constituents (lipid and collagen) and was not present in plaques induced by multidirectional WSS. These findings demonstrate that NP accumulation can be used to differentiate between unstable and stable murine atherosclerosis, but accumulation kinetics are not directly influenced by the WSS condition. This tool could be used as a diagnostic to evaluate the efficacy of experimental therapeutics for atherosclerosis.


Asunto(s)
Apolipoproteínas E/genética , Aterosclerosis/diagnóstico por imagen , Ácido Fólico/administración & dosificación , Gadolinio/química , Miocitos del Músculo Liso/química , Placa Aterosclerótica/diagnóstico por imagen , Animales , Aterosclerosis/genética , Velocidad del Flujo Sanguíneo , Medios de Contraste/administración & dosificación , Medios de Contraste/química , Medios de Contraste/farmacocinética , Diagnóstico Diferencial , Modelos Animales de Enfermedad , Femenino , Ácido Fólico/química , Ácido Fólico/farmacocinética , Gadolinio/farmacocinética , Imagen por Resonancia Magnética , Ratones , Ratones Noqueados , Nanopartículas , Placa Aterosclerótica/genética , Resistencia al Corte , Estrés Mecánico
8.
J Biomech ; 128: 110720, 2021 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-34482227

RESUMEN

Atherosclerosis is a lipid driven chronic inflammatory disease that is characterized by the formation of plaques at predilection sites. These predilection sites (side branches, curved segments, and bifurcations) have often been associated with disturbed shear stress profiles. However, in addition to shear stress, endothelial cells also experience artery wall strain that could contribute to atherosclerosis progression. Herein, we describe a method to accurately obtain these shear stress and strain profiles. We developed a fluid-structure interaction (FSI) framework for modelling arteries within a commercially available package (Abaqus, version 6.14) that included known prestresses (circumferential, axial and pressure associated). In addition, we co-registered 3D histology to a micro-CT-derived 3D reconstruction of an atherosclerotic carotid artery from a cholesterol-fed ApoE-/- mouse to include the spatial distribution of lipids within a subject-specific model. The FSI model also incorporated a nonlinear hyperelastic material model with regionally-varying properties that distinguished between healthy vessel wall and plaque. FSI predicted a lower shear stress than CFD (~-12%), but further decreases in plaque regions with softer properties (~-24%) were dependent on the approach used to implement the prestresses in the artery wall. When implemented with our new hybrid approach (zero prestresses in regions of lipid deposition), there was significant heterogeneity in endothelial shear stress in the atherosclerotic artery due to variations in stiffness and, in turn, wall strain. In conclusion, when obtaining endothelial shear stress and strain in diseased arteries, a careful consideration of prestresses is necessary. This paper offers a way to implement them.


Asunto(s)
Aterosclerosis , Modelos Cardiovasculares , Animales , Arterias Carótidas , Células Endoteliales , Ratones , Resistencia al Corte , Estrés Mecánico
9.
J Biomech ; 115: 110127, 2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33223144

RESUMEN

The lens capsule of the eye is important in focusing light onto the retina during the process of accommodation and, in later life, housing a prosthetic lens implanted during cataract surgery. Though considerable modeling work has characterized the mechanics of accommodation, little has been done to understand the mechanics of the lens capsule after cataract surgery. As such, we present the first 3-D finite element model of the post-surgical human lens capsule with an implanted tension ring and, separately, an intraocular lens to characterize the altered stress field compared to that in a model of the native lens capsule. All finite element models employed a Holzapfel hyperelastic constitutive model with regional variations in anisotropy. The post-surgical lens capsule demonstrated a dramatic perturbation to the stress field with mostly large reductions in stresses (except at the equator where the implant contacts the capsule) compared to native, wherein maximal changes in Cauchy stress were -100% and -145% for the tension ring and intraocular lens, respectively. However, implantation of the tension ring produced a more uniform stress field compared to the IOL. The magnitudes and distribution of the perturbed stress field may be an important driver of the fibrotic response of inhabiting lens epithelial cells and associated lens capsule remodeling after cataract surgery. Thus, the mechanical effects of an implant on the lens capsule could be an essential consideration in the design of intraocular lenses, particularly those with an accommodative feature.


Asunto(s)
Extracción de Catarata , Catarata , Cápsula del Cristalino , Lentes Intraoculares , Anisotropía , Humanos , Diseño de Prótesis
10.
EuroIntervention ; 14(10): 1129-1135, 2018 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-29616625

RESUMEN

AIMS: In vivo validation of coronary optical coherence tomography (OCT) against histology and the effects of plaque burden (PB) on plaque classification remain unreported. We aimed to investigate this in a porcine model with human-like coronary atherosclerosis. METHODS AND RESULTS: Five female Yucatan D374Y-PCSK9 transgenic hypercholesterolaemic minipigs were implanted with a coronary shear-modifying stent to induce advanced atherosclerosis. OCT frames (n=201) were obtained 34 weeks after implantation. Coronary arteries were perfusion-fixed, serially sectioned and co-registered with OCT using a validated algorithm. Lesions were adjudicated using the Virmani classification and PB assessed from histology. OCT had a high sensitivity, but modest specificity (92.9% and 74.6%), for identifying fibrous cap atheroma (FCA). The reduced specificity for OCT was due to misclassification of plaques with histologically defined pathological intimal thickening (PIT) as FCA (46.1% of the frames with histological PIT were misclassified). PIT lesions misclassified as FCA by OCT had a statistically higher PB than in other OCT frames (median 32.0% versus 13.4%; p<0.0001). Misclassification of PIT lesions by OCT occurred when PB exceeded approximately 20%. CONCLUSIONS: Compared with histology, in vivo OCT classification of FCA had high sensitivity but reduced specificity due to misclassification of PITs with high PB.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Animales , Vasos Coronarios , Femenino , Humanos , Proproteína Convertasa 9 , Porcinos , Tomografía de Coherencia Óptica
11.
Ann Biomed Eng ; 45(4): 898-909, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27796516

RESUMEN

Exposure of endothelial cells to low and multidirectional blood flow is known to promote a pro-atherogenic phenotype. The mechanics of the vessel wall is another important mechano-stimulus within the endothelial cell environment, but no study has examined whether changes in the magnitude and direction of cell stretch can be pro-atherogenic. Herein, we developed a custom cell stretching device to replicate the in vivo stretch environment of the endothelial cell and examined whether low and multidirectional stretch promote nuclear translocation of NF-κB. A fluid-structure interaction model of the device demonstrated a nearly uniform strain within the region of cell attachment and a negligible magnitude of shear stress due to cyclical stretching of the cells in media. Compared to normal cyclical stretch, a low magnitude of cyclical stretch or no stretch caused increased expression of nuclear NF-κB (p = 0.09 and p < 0.001, respectively). Multidirectional stretch also promoted significant nuclear NF-κB expression, comparable to the no stretch condition, which was statistically higher than the low (p < 0.001) and normal (p < 0.001) stretch conditions. This is the first study to show that stretch conditions analogous to atherogenic blood flow profiles can similarly promote a pro-atherogenic endothelial cell phenotype, which supports a role for disturbed vessel wall mechanics as a pathological cell stimulus in the development of advanced atherosclerotic plaques.


Asunto(s)
Aterosclerosis/metabolismo , Núcleo Celular/metabolismo , Células Endoteliales/metabolismo , Regulación de la Expresión Génica , FN-kappa B/metabolismo , Estrés Mecánico , Aterosclerosis/patología , Línea Celular , Núcleo Celular/patología , Células Endoteliales/patología , Humanos , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patología
12.
R Soc Open Sci ; 3(10): 160588, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27853578

RESUMEN

The precise flow characteristics that promote different atherosclerotic plaque types remain unclear. We previously developed a blood flow-modifying cuff for ApoE-/- mice that induces the development of advanced plaques with vulnerable and stable features upstream and downstream of the cuff, respectively. Herein, we sought to test the hypothesis that changes in flow magnitude promote formation of the upstream (vulnerable) plaque, whereas altered flow direction is important for development of the downstream (stable) plaque. We instrumented ApoE-/- mice (n = 7) with a cuff around the left carotid artery and imaged them with micro-CT (39.6 µm resolution) eight to nine weeks after cuff placement. Computational fluid dynamics was then performed to compute six metrics that describe different aspects of atherogenic flow in terms of wall shear stress magnitude and/or direction. In a subset of four imaged animals, we performed histology to confirm the presence of advanced plaques and measure plaque length in each segment. Relative to the control artery, the region upstream of the cuff exhibited changes in shear stress magnitude only (p < 0.05), whereas the region downstream of the cuff exhibited changes in shear stress magnitude and direction (p < 0.05). These data suggest that shear stress magnitude contributes to the formation of advanced plaques with a vulnerable phenotype, whereas variations in both magnitude and direction promote the formation of plaques with stable features.

13.
Sci Rep ; 6: 29643, 2016 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-27404994

RESUMEN

The majority of (mammalian) cells in our body are sensitive to mechanical forces, but little work has been done to develop assays to monitor mechanosensor activity. Furthermore, it is currently impossible to use mechanosensor activity to drive gene expression. To address these needs, we developed the first mammalian mechanosensitive synthetic gene network to monitor endothelial cell shear stress levels and directly modulate expression of an atheroprotective transcription factor by shear stress. The technique is highly modular, easily scalable and allows graded control of gene expression by mechanical stimuli in hard-to-transfect mammalian cells. We call this new approach mechanosyngenetics. To insert the gene network into a high proportion of cells, a hybrid transfection procedure was developed that involves electroporation, plasmids replication in mammalian cells, mammalian antibiotic selection, a second electroporation and gene network activation. This procedure takes 1 week and yielded over 60% of cells with a functional gene network. To test gene network functionality, we developed a flow setup that exposes cells to linearly increasing shear stress along the length of the flow channel floor. Activation of the gene network varied logarithmically as a function of shear stress magnitude.


Asunto(s)
Regulación de la Expresión Génica , Expresión Génica , Redes Reguladoras de Genes , Mecanotransducción Celular , Supervivencia Celular , Células Cultivadas , Células Endoteliales/metabolismo , Células HeLa/metabolismo , Humanos , Factores de Transcripción de Tipo Kruppel/genética , Estrés Mecánico , Activación Transcripcional , Transfección
14.
Physiol Rep ; 4(6)2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27009275

RESUMEN

The discovery of the human genome has unveiled new fields of genomics, transcriptomics, and proteomics, which has produced paradigm shifts on how to study disease mechanisms, wherein a current central focus is the understanding of how gene signatures and gene networks interact within cells. These gene function studies require manipulating genes either through activation or inhibition, which can be achieved by temporarily permeabilizing the cell membrane through transfection to delivercDNAorRNAi. An efficient transfection technique is electroporation, which applies an optimized electric pulse to permeabilize the cells of interest. When the molecules are applied on top of seeded cells, it is called "direct" transfection and when the nucleic acids are printed on the substrate and the cells are seeded on top of them, it is termed "reverse" transfection. Direct transfection has been successfully applied in previous studies, whereas reverse transfection has recently gained more attention in the context of high-throughput experiments. Despite the emerging importance, studies comparing the efficiency of the two methods are lacking. In this study, a model for electroporation of cells in situ is developed to address this deficiency. The results indicate that reverse transfection is less efficient than direct transfection. However, the model also predicts that by increasing the concentration of deliverable molecules by a factor of 2 or increasing the applied voltage by 20%, reverse transfection can be approximately as efficient as direct transfection.


Asunto(s)
Permeabilidad de la Membrana Celular , Membrana Celular/metabolismo , Simulación por Computador , Electroporación , Células Endoteliales/metabolismo , Modelos Genéticos , ARN Interferente Pequeño/metabolismo , Transfección/métodos , Animales , Transporte Biológico , Células Cultivadas , Difusión , Humanos , Análisis Numérico Asistido por Computador , Porosidad , Interferencia de ARN , Programas Informáticos
15.
Thromb Haemost ; 115(3): 474-83, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26842798

RESUMEN

Blood flow is an essential contributor to plaque growth, composition and initiation. It is sensed by endothelial cells, which react to blood flow by expressing > 1000 genes. The sheer number of genes implies that one needs genomic techniques to unravel their response in disease. Individual genomic studies have been performed but lack sufficient power to identify subtle changes in gene expression. In this study, we investigated whether a systematic meta-analysis of available microarray studies can improve their consistency. We identified 17 studies using microarrays, of which six were performed in vivo and 11 in vitro. The in vivo studies were disregarded due to the lack of the shear profile. Of the in vitro studies, a cross-platform integration of human studies (HUVECs in flow cells) showed high concordance (> 90 %). The human data set identified > 1600 genes to be shear responsive, more than any other study and in this gene set all known mechanosensitive genes and pathways were present. A detailed network analysis indicated a power distribution (e. g. the presence of hubs), without a hierarchical organisation. The average cluster coefficient was high and further analysis indicated an aggregation of 3 and 4 element motifs, indicating a high prevalence of feedback and feed forward loops, similar to prokaryotic cells. In conclusion, this initial study presented a novel method to integrate human-based mechanosensitive studies to increase its power. The robust network was large, contained all known mechanosensitive pathways and its structure revealed hubs, and a large aggregate of feedback and feed forward loops.


Asunto(s)
Velocidad del Flujo Sanguíneo , Biología Computacional , Análisis de Secuencia por Matrices de Oligonucleótidos , Secuencias de Aminoácidos , Animales , Análisis por Conglomerados , Diseño de Fármacos , Células Endoteliales/citología , Femenino , Perfilación de la Expresión Génica , Células Endoteliales de la Vena Umbilical Humana , Humanos , Masculino , Ratones , Transducción de Señal , Programas Informáticos , Estrés Mecánico
16.
J R Soc Interface ; 12(112)2015 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-26559685

RESUMEN

Plaques vulnerable to rupture are characterized by a thin and stiff fibrous cap overlaying a soft lipid-rich necrotic core. The ability to measure local plaque stiffness directly to quantify plaque stress and predict rupture potential would be very attractive, but no current technology does so. This study seeks to validate the use of Brillouin microscopy to measure the Brillouin frequency shift, which is related to stiffness, within vulnerable plaques. The left carotid artery of an ApoE(-/-)mouse was instrumented with a cuff that induced vulnerable plaque development in nine weeks. Adjacent histological sections from the instrumented and control arteries were stained for either lipids or collagen content, or imaged with confocal Brillouin microscopy. Mean Brillouin frequency shift was 15.79 ± 0.09 GHz in the plaque compared with 16.24 ± 0.15 (p < 0.002) and 17.16 ± 0.56 GHz (p < 0.002) in the media of the diseased and control vessel sections, respectively. In addition, frequency shift exhibited a strong inverse correlation with lipid area of -0.67 ± 0.06 (p < 0.01) and strong direct correlation with collagen area of 0.71 ± 0.15 (p < 0.05). This is the first study, to the best of our knowledge, to apply Brillouin spectroscopy to quantify atherosclerotic plaque stiffness, which motivates combining this technology with intravascular imaging to improve detection of vulnerable plaques in patients.


Asunto(s)
Colágeno/metabolismo , Metabolismo de los Lípidos , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patología , Rigidez Vascular , Animales , Colágeno/genética , Modelos Animales de Enfermedad , Ratones , Ratones Noqueados , Microscopía Confocal , Placa Aterosclerótica/genética
17.
Circulation ; 132(11): 1003-12, 2015 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-26179404

RESUMEN

BACKGROUND: Although disturbed flow is thought to play a central role in the development of advanced coronary atherosclerotic plaques, no causal relationship has been established. We evaluated whether inducing disturbed flow would cause the development of advanced coronary plaques, including thin cap fibroatheroma. METHODS AND RESULTS: D374Y-PCSK9 hypercholesterolemic minipigs (n=5) were instrumented with an intracoronary shear-modifying stent (SMS). Frequency-domain optical coherence tomography was obtained at baseline, immediately poststent, 19 weeks, and 34 weeks, and used to compute shear stress metrics of disturbed flow. At 34 weeks, plaque type was assessed within serially collected histological sections and coregistered to the distribution of each shear metric. The SMS caused a flow-limiting stenosis, and blood flow exiting the SMS caused regions of increased shear stress on the outer curvature and large regions of low and multidirectional shear stress on the inner curvature of the vessel. As a result, plaque burden was ≈3-fold higher downstream of the SMS than both upstream of the SMS and in the control artery (P<0.001). Advanced plaques were also primarily observed downstream of the SMS, in locations initially exposed to both low (P<0.002) and multidirectional (P<0.002) shear stress. Thin cap fibroatheroma regions demonstrated significantly lower shear stress that persisted over the duration of the study in comparison with other plaque types (P<0.005). CONCLUSIONS: These data support a causal role for lowered and multidirectional shear stress in the initiation of advanced coronary atherosclerotic plaques. Persistently lowered shear stress appears to be the principal flow disturbance needed for the formation of thin cap fibroatheroma.


Asunto(s)
Aterosclerosis/etiología , Aterosclerosis/fisiopatología , Vasos Coronarios/fisiopatología , Hipercolesterolemia/complicaciones , Placa Aterosclerótica/etiología , Placa Aterosclerótica/fisiopatología , Flujo Sanguíneo Regional/fisiología , Animales , Animales Modificados Genéticamente , Angiografía Coronaria , Circulación Coronaria/fisiología , Modelos Animales de Enfermedad , Hemodinámica/fisiología , Hipercolesterolemia/genética , Hipercolesterolemia/fisiopatología , Proproteína Convertasas/genética , Resistencia al Corte/fisiología , Stents , Estrés Mecánico , Porcinos , Porcinos Enanos , Factores de Tiempo , Tomografía de Coherencia Óptica
18.
J R Soc Interface ; 12(106)2015 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-25808341

RESUMEN

In this review, we discuss new emerging medical applications of the rapidly evolving field of mammalian synthetic biology. We start with simple mammalian synthetic biological components and move towards more complex and therapy-oriented gene circuits. A comprehensive list of ON-OFF switches, categorized into transcriptional, post-transcriptional, translational and post-translational, is presented in the first sections. Subsequently, Boolean logic gates, synthetic mammalian oscillators and toggle switches will be described. Several synthetic gene networks are further reviewed in the medical applications section, including cancer therapy gene circuits, immuno-regulatory networks, among others. The final sections focus on the applicability of synthetic gene networks to drug discovery, drug delivery, receptor-activating gene circuits and mammalian biomanufacturing processes.


Asunto(s)
Biotecnología/tendencias , Sistemas de Liberación de Medicamentos/tendencias , Descubrimiento de Drogas/tendencias , Redes Reguladoras de Genes/genética , Genes Sintéticos/genética , Biología Sintética/tendencias , Animales , Mamíferos
19.
Proc Natl Acad Sci U S A ; 111(38): 13876-81, 2014 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-25201985

RESUMEN

Increased flow resistance is responsible for the elevated intraocular pressure characteristic of glaucoma, but the cause of this resistance increase is not known. We tested the hypothesis that altered biomechanical behavior of Schlemm's canal (SC) cells contributes to this dysfunction. We used atomic force microscopy, optical magnetic twisting cytometry, and a unique cell perfusion apparatus to examine cultured endothelial cells isolated from the inner wall of SC of healthy and glaucomatous human eyes. Here we establish the existence of a reduced tendency for pore formation in the glaucomatous SC cell--likely accounting for increased outflow resistance--that positively correlates with elevated subcortical cell stiffness, along with an enhanced sensitivity to the mechanical microenvironment including altered expression of several key genes, particularly connective tissue growth factor. Rather than being seen as a simple mechanical barrier to filtration, the endothelium of SC is seen instead as a dynamic material whose response to mechanical strain leads to pore formation and thereby modulates the resistance to aqueous humor outflow. In the glaucomatous eye, this process becomes impaired. Together, these observations support the idea of SC cell stiffness--and its biomechanical effects on pore formation--as a therapeutic target in glaucoma.


Asunto(s)
Citoesqueleto , Células Endoteliales , Ojo , Glaucoma , Microscopía de Fuerza Atómica , Células Cultivadas , Citoesqueleto/metabolismo , Citoesqueleto/patología , Células Endoteliales/metabolismo , Células Endoteliales/patología , Ojo/metabolismo , Ojo/patología , Glaucoma/metabolismo , Glaucoma/patología , Humanos
20.
Exp Eye Res ; 127: 224-35, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25128579

RESUMEN

The bulk of aqueous humor passing through the conventional outflow pathway must cross the inner wall endothelium of Schlemm's canal (SC), likely through micron-sized transendothelial pores. SC pore density is reduced in glaucoma, possibly contributing to obstructed aqueous humor outflow and elevated intraocular pressure (IOP). Little is known about the mechanisms of pore formation; however, pores are often observed near dome-like cellular outpouchings known as giant vacuoles (GVs) where significant biomechanical strain acts on SC cells. We hypothesize that biomechanical strain triggers pore formation in SC cells. To test this hypothesis, primary human SC cells were isolated from three non-glaucomatous donors (aged 34, 44 and 68), and seeded on collagen-coated elastic membranes held within a membrane stretching device. Membranes were then exposed to 0%, 10% or 20% equibiaxial strain, and the cells were aldehyde-fixed 5 min after the onset of strain. Each membrane contained 3-4 separate monolayers of SC cells as replicates (N = 34 total monolayers), and pores were assessed by scanning electron microscopy in 12 randomly selected regions (∼65,000 µm(2) per monolayer). Pores were identified and counted by four independent masked observers. Pore density increased with strain in all three cell lines (p < 0.010), increasing from 87 ± 36 pores/mm(2) at 0% strain to 342 ± 71 at 10% strain; two of the three cell lines showed no additional increase in pore density beyond 10% strain. Transcellular "I-pores" and paracellular "B-pores" both increased with strain (p < 0.038), however B-pores represented the majority (76%) of pores. Pore diameter, in contrast, appeared unaffected by strain (p = 0.25), having a mean diameter of 0.40 µm for I-pores (N = 79 pores) and 0.67 µm for B-pores (N = 350 pores). Pore formation appears to be a mechanosensitive process that is triggered by biomechanical strain, suggesting that SC cells have the ability to modulate local pore density and filtration characteristics of the inner wall endothelium based on local biomechanical cues. The molecular mechanisms of pore formation and how they become altered in glaucoma may be studied in vitro using stretched SC cells.


Asunto(s)
Humor Acuoso/metabolismo , Células Endoteliales/fisiología , Espacio Extracelular , Espacio Intracelular , Limbo de la Córnea/citología , Esclerótica/fisiología , Estrés Mecánico , Adulto , Anciano , Comunicación Celular , Recuento de Células , Células Cultivadas , Células Endoteliales/ultraestructura , Humanos , Microscopía Electrónica de Rastreo , Porosidad , Esclerótica/ultraestructura , Donantes de Tejidos , Vacuolas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...